L'image peut être une représentation.
Voir les spécifications pour les détails du produit.
P51-15-A-L-P-20MA-000-000

P51-15-A-L-P-20MA-000-000

Introduction

The P51-15-A-L-P-20MA-000-000 is a crucial component in the field of electronic devices, offering a wide range of applications and functionalities. This entry will provide an in-depth overview of the product, including its basic information, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Electronic Component
  • Use: Signal Processing and Control
  • Characteristics: High Precision, Low Power Consumption
  • Package: Surface Mount
  • Essence: Pressure Sensor
  • Packaging/Quantity: Tape & Reel, 2500 units per reel

Specifications

  • Model: P51-15-A-L-P-20MA-000-000
  • Pressure Range: 0 to 15 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% Full Scale
  • Operating Temperature: -40°C to 125°C
  • Supply Voltage: 10-30 VDC
  • Long-Term Stability: ±0.25% Full Scale per year

Detailed Pin Configuration

  1. Vcc (Supply Voltage)
  2. GND (Ground)
  3. Output
  4. N/C (Not Connected)

Functional Features

  • High Accuracy: Provides precise pressure measurement with an accuracy of ±0.5% full scale.
  • Wide Operating Temperature Range: Suitable for use in extreme environmental conditions ranging from -40°C to 125°C.
  • Low Power Consumption: Consumes minimal power, making it energy-efficient.
  • Long-Term Stability: Maintains consistent performance over extended periods with a stability of ±0.25% full scale per year.

Advantages and Disadvantages

Advantages

  • Accurate and reliable pressure sensing
  • Wide operating temperature range
  • Low power consumption

Disadvantages

  • Limited pressure range (0 to 15 psi)
  • Requires external signal conditioning for specific applications

Working Principles

The P51-15-A-L-P-20MA-000-000 operates on the principle of piezoresistive sensing, where changes in pressure cause a corresponding change in the resistance of the sensor. This change is then converted into a 4-20 mA output signal, proportional to the applied pressure.

Detailed Application Field Plans

The P51-15-A-L-P-20MA-000-000 finds extensive use in various industries, including: - Industrial Automation: Pressure monitoring in pneumatic and hydraulic systems - HVAC Systems: Air flow and duct pressure measurements - Medical Devices: Patient monitoring and respiratory equipment - Automotive: Tire pressure monitoring and fuel system pressure sensing

Detailed and Complete Alternative Models

  • P51-30-A-P-I12-5V-000-000: Higher pressure range (0 to 30 psi) with 0-5V output
  • P51-100-A-P-I12-5V-000-000: Extended pressure range (0 to 100 psi) with 0-5V output
  • P51-500-A-P-I12-5V-000-000: High-pressure range (0 to 500 psi) with 0-5V output

In conclusion, the P51-15-A-L-P-20MA-000-000 is a versatile and reliable pressure sensor that caters to diverse industrial and commercial applications, offering high precision and robust performance.

Word Count: 477 words

Énumérez 10 questions et réponses courantes liées à l'application de P51-15-A-L-P-20MA-000-000 dans les solutions techniques

  1. What is the P51-15-A-L-P-20MA-000-000?

    • The P51-15-A-L-P-20MA-000-000 is a pressure transducer designed to convert pressure into an analog electrical signal.
  2. What is the operating range of the P51-15-A-L-P-20MA-000-000?

    • The operating range of the P51-15-A-L-P-20MA-000-000 is typically from 0 to 150 psi.
  3. How is the P51-15-A-L-P-20MA-000-000 installed?

    • The P51-15-A-L-P-20MA-000-000 can be installed using standard NPT fittings and should be mounted in a location that provides accurate pressure readings.
  4. What are the typical applications for the P51-15-A-L-P-20MA-000-000?

    • The P51-15-A-L-P-20MA-000-000 is commonly used in industrial automation, hydraulic systems, and HVAC applications.
  5. What is the output signal of the P51-15-A-L-P-20MA-000-000?

    • The P51-15-A-L-P-20MA-000-000 produces a 4-20mA analog output signal proportional to the measured pressure.
  6. Is the P51-15-A-L-P-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-15-A-L-P-20MA-000-000 is often designed to withstand harsh industrial environments and is available with various environmental protection options.
  7. Can the P51-15-A-L-P-20MA-000-000 be used for measuring gas pressure?

    • Yes, the P51-15-A-L-P-20MA-000-000 can be used for measuring gas pressure as long as it is within its specified pressure range.
  8. What are the power requirements for the P51-15-A-L-P-20MA-000-000?

    • The P51-15-A-L-P-20MA-000-000 typically operates on a 12-36V DC power supply.
  9. Does the P51-15-A-L-P-20MA-000-000 require calibration?

    • Yes, periodic calibration is recommended to ensure accurate and reliable performance.
  10. Are there any special considerations for wiring the P51-15-A-L-P-20MA-000-000?

    • It's important to follow the manufacturer's guidelines for wiring and to ensure proper grounding to avoid signal interference.