AD8232ACPZ-R7 belongs to the category of integrated analog front-end (AFE) devices.
It is primarily used for monitoring biopotential signals, such as electrocardiogram (ECG) signals.
AD8232ACPZ-R7 is available in a small form factor package, specifically LFCSP (lead frame chip scale package).
The essence of AD8232ACPZ-R7 lies in its ability to accurately acquire and amplify biopotential signals while minimizing noise and interference.
This product is typically packaged in reels or tubes, with a quantity of 2500 units per reel/tube.
AD8232ACPZ-R7 has the following pin configuration:
AD8232ACPZ-R7 operates based on the principle of amplifying and filtering biopotential signals. It utilizes a differential amplifier to amplify the small voltage differences between the IN+ and IN- inputs. The amplified signal is then filtered to remove unwanted noise and interference, resulting in a clean and reliable output.
AD8232ACPZ-R7 finds extensive application in various fields, including:
Some alternative models that offer similar functionality to AD8232ACPZ-R7 include:
These alternative models provide different features and specifications, allowing designers to choose the most suitable option for their specific application requirements.
Word count: 529
Question: What is the typical supply voltage range for AD8232ACPZ-R7?
Answer: The typical supply voltage range for AD8232ACPZ-R7 is 2.0V to 3.5V.
Question: What is the input bias current of AD8232ACPZ-R7?
Answer: The input bias current of AD8232ACPZ-R7 is typically 50pA.
Question: Can AD8232ACPZ-R7 be used in ECG monitoring applications?
Answer: Yes, AD8232ACPZ-R7 is specifically designed for ECG monitoring applications.
Question: What is the common-mode rejection ratio (CMRR) of AD8232ACPZ-R7?
Answer: The CMRR of AD8232ACPZ-R7 is typically 80dB.
Question: Does AD8232ACPZ-R7 have a shutdown feature?
Answer: Yes, AD8232ACPZ-R7 has a shutdown feature to conserve power when not in use.
Question: What is the bandwidth of AD8232ACPZ-R7?
Answer: The bandwidth of AD8232ACPZ-R7 is typically 0.5Hz to 40Hz.
Question: Can AD8232ACPZ-R7 be used in portable medical devices?
Answer: Yes, AD8232ACPZ-R7 is suitable for use in portable medical devices due to its low power consumption.
Question: What is the input impedance of AD8232ACPZ-R7?
Answer: The input impedance of AD8232ACPZ-R7 is typically 2MΩ.
Question: Is AD8232ACPZ-R7 RoHS compliant?
Answer: Yes, AD8232ACPZ-R7 is RoHS compliant, making it suitable for environmentally conscious designs.
Question: Can AD8232ACPZ-R7 be used in wearable health and fitness monitoring devices?
Answer: Yes, AD8232ACPZ-R7 is well-suited for use in wearable health and fitness monitoring devices due to its small size and low power requirements.